作者投稿和查稿 主编审稿 专家审稿 编委审稿 远程编辑

计算机工程 ›› 2009, Vol. 35 ›› Issue (11): 254-255,.

• 工程应用技术与实现 • 上一篇    下一篇

S7-300中Modbus协议的免驱动应用

陈 群   

  1. (南京工业大学信息科学与工程学院,南京210009)
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2009-06-05 发布日期:2009-06-05

Non-driver Application of Modbus Protocol in S7-300

CHEN Qun   

  1. (College of Information Science and Engineering, Nanjing University of Technology, Nanjing 210009)
  • Received:1900-01-01 Revised:1900-01-01 Online:2009-06-05 Published:2009-06-05

摘要: 介绍在SIMATIC S7-300 PLC控制系统中,利用对串口通信模块的软件编程,实现Modbus RTU master/slave通信的应用。实际生产应用表明,该方案在保证有效可靠的通信质量的同时,免除购买Siemens公司Modbus协议驱动模块的格外开销,具有值得推广的经济意义。

关键词: 可编程逻辑控制器, Modbus 协议, 串行通信

Abstract: This paper describes the realization of Modbus RTU master/salve protocol based on SIMATIC S7-300 PLC point-to-point communication module. In a practical packaging control system, data is transmitted reliably and effectively. The scheme is worth promoting economic significance, for avoiding the expense of Siemens driver module of Modbus protocol.

Key words: Programmable Logic Controller(PLC), Modbus protocol, serial communication

中图分类号: